Siemens alarm 400252: Error in internal communication with NCK

SINUMERIK PLC system alarm · Siemens 840D/810D powerline

What it means

An error occurred during data transmission between the PLC and the NCK over their internal interface. Siemens documents this specifically for FM-NC configurations, where the NC function runs as an FM module and talks to the S7 CPU across the backplane. A restart of the NCK is prescribed; repeated occurrence indicates a hardware-level bus problem.

Likely causes

  • Interruption of internal NCK-to-CPU transmission (FM-NC)
  • Seating/contact problem of the FM-NC module or backplane connector
  • Transient system error cleared by restart

Triage note: (FM-NC only). Companion alarms 400255/400256/400257 report the same conditions for the second NCK (NCK2) in dual-NCK systems.

Need the part urgently?

Send us alarm 400252 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog