RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 400254

Siemens alarm 400254: Checksum error found: %1

SINUMERIK PLC system alarm · Siemens 840D/810D powerline

What it means

A checksum test detected corruption in safety-relevant PLC code or safety-relevant data; %1 identifies the code section or table concerned. The Safety Integrated monitoring functions implemented in the PLC may consequently be damaged or unreliable. Power the control OFF/ON immediately, and hand it to the service department if the error returns.

Likely causes

  • Corrupted safety-relevant program/data in PLC load memory
  • Failed or interrupted download of F-capable PLC project
  • Hardware memory defect affecting F data

Triage note: Safety-relevant: do not keep operating the machine with this alarm active. Reaction: switch control OFF - ON.

Need the part urgently?

Send us alarm 400254 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog