Siemens alarm 4024: Invalid axis configuration due to missing axis container machine data

SINUMERIK NCK general alarm · Siemens 840D/810D powerline

What it means

The NCK could not build the axis configuration because axis-container machine data is missing. According to the Diagnostics Guide this error can only occur as the result of a communication error, which is indicated separately by further alarms. The NC start-up aborts until the machine data is available again.

Likely causes

  • Communication failure between NCK components during power-up
  • Incomplete transfer of commissioning/machine data
  • Underlying bus or memory fault indicated by companion alarms

Triage note: Diagnose the separately reported communication alarms first; re-power and reload the NC data.