RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 4099

Siemens alarm 4099: %1 error(s) during processing of MD initialization

SINUMERIK NCK general alarm · Siemens 840D/810D powerline

What it means

Errors occurred while the NCK processed machine data initializations at power-up; parameter %1 gives the number of errors. The power-up log files contain a detailed description of each error. The NC is not ready until the faulty machine data is corrected.

Likely causes

  • Invalid machine data values introduced by manual editing
  • Archive/INI files with wrong syntax or wrong version loaded at boot
  • Option-dependent machine data set without the corresponding option

Triage note: Clear with RESET after correcting the machine data; consult the power-up logs for the specific failing MDs.

Need the part urgently?

Send us alarm 4099 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog