Siemens alarm 410150: Area in M group decoder list is too large

SINUMERIK PLC system alarm · Siemens 840D/810D powerline

What it means

More M-function groups were declared to the PLC than fit into the reserved decoder-list area, so the static M-group decoding table overflows. The number of M groups handed to the PLC has to be reduced. This occurs during commissioning of extended PLC-side M functions, not during normal production.

Likely causes

  • Excessive number of PLC M groups defined in the interface configuration
  • M-group table enlarged without checking area limits

Triage note: Remedy: reduce the number of groups; program continuation internal.