Siemens alarm 430000: F diagnostic: PLC project inconsistent

SINUMERIK PLC system alarm · Siemens 840D/810D powerline

What it means

The F (fail-safe) diagnostics could not execute because the PLC project is inconsistent or the configured NCU firmware version is unsupported for the F functionality loaded. Since fail-safe execution cannot be validated, the system treats run-up as invalid until a consistent project is present. Per Siemens the configured NCU firmware (TIA Portal) must be at least V4.8 and a consistent PLC project reloaded.

Likely causes

  • Partially loaded or mixed-version F-compatible PLC project
  • TIA Portal project compiled for newer firmware than the NCU runs
  • Download interrupted leaving inconsistent F blocks

Triage note: Safety Integrated context; program continuation switch control OFF - ON. See also 430001-430010 (F-module I/O errors) and 430101-430105 (F_DP communication).

Need the part urgently?

Send us alarm 430000 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog