Siemens alarm 431001: The safety mode of the F-PLC has been deactivated.

SINUMERIK PLC system alarm · Siemens 840D/810D powerline

What it means

The user deliberately switched off the safety mode of the fail-safe PLC; as a consequence certain automatic error-control measures of the F runtime are inactive. Siemens notes the condition is informational-plus-warning in nature and that the safety mode reactivates at the next PLC power-on. The machine must not be operated in applications relying on the deactivated F functions until then.

Likely causes

  • Intentional deactivation during commissioning/testing of the F program
  • Service personnel disabling F mode temporarily for diagnostics

Triage note: Clears/reactivates at next PLC power-on; program continuation switch control OFF - ON.