What it means

The cycle was called without a usable feedrate, i.e. the feed parameter evaluates to zero or is missing, so material removal cannot proceed. On lathes without a Y axis in the G18 plane certain feed specifications are also rejected. Correct the feed parameter on the cycle call.

Likely causes

  • Feed parameter (e.g. MFR/MRF or F word) omitted or set to zero
  • Feed type selection inconsistent with the tool used
  • Program branch skips the block that assigns the feed