Siemens alarm 61017: Function %4 not present in NCK

SINUMERIK function alarm · Siemens 840D/810D powerline

What it means

The called cycle uses an NCK function that does not exist in the control because the corresponding software option is not enabled. Parameter %4 names the missing function. The cycle cannot run on this configuration until the option is supplied and activated.

Likely causes

  • Required SINUMERIK software option not ordered/activated
  • NC software level too low for the cycle version used
  • Program copied from a control with more options fitted

Need the part urgently?

Send us alarm 61017 with your machine details — typical RFQ turnaround is 24–48h.