Siemens alarm 61027: Subroutine %4 does not exist

SINUMERIK function alarm · Siemens 840D/810D powerline

What it means

The cycle refers to a contour subroutine named in parameter %4 which cannot be found in program storage. This is typical for contour cycles that read their geometry from a separately programmed contour description. Check the CYCLE62-style contour call and make sure the named routines exist in the active program storage.

Likely causes

  • Contour subroutine deleted, renamed or never transferred to the NCK
  • Subroutine located in a directory not searched by the cycle
  • Typographical error in the contour/subroutine name