RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 611-IR-LED2-red

Siemens alarm 611-IR-LED2-red: Infeed/monitoring module LED 2 (red): 5 V voltage level faulted

SIMODRIVE 611 I/R module LED indication (6SN1145/6SN1146) · SIMODRIVE 611D/611U

What it means

The internal +5 V electronics level is faulted; as with LED 1 the gating pulses of the entire drive group are suppressed. The +5 V rail feeds the digital electronics of every control board in the group, so both source-side and consumer-side failures present identically.

Likely causes

  • infeed 5 V converter defective
  • short circuit on the 5 V distribution through the equipment bus
  • defective control/regulator board loading the rail
  • connector corrosion/contamination raising rail resistance

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 611-IR-LED2-red with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog