RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 61106

Siemens alarm 61106: Number of or distance between circular elements incorrectly defined

SINUMERIK function alarm · Siemens 840D/810D powerline

What it means

The layout of holes or slots on a full circle is geometrically impossible with the given NUM (quantity) and INDA (angle) parameters, e.g. elements overlapping or not fitting the pitch circle. Affecting hole-pattern and slot cycles, the alarm halts the cycle before positioning starts. Re-parameterize quantity and angular spacing so the pattern closes correctly.

Likely causes

  • NUM x INDA exceeds or falls short of the full-circle angle
  • Angular spacing smaller than element width
  • Pitch-circle radius too small for the number of elements

Triage note: Triggered by HOLES2, LONGHOLE, SLOT1, SLOT2.

Need the part urgently?

Send us alarm 61106 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog