Siemens alarm 61117: Active tool radius is smaller than or equal to zero

SINUMERIK function alarm · Siemens 840D/810D powerline

What it means

The radius of the currently active tool reads zero or negative, which makes radius-compensated cycle motions undefined. Cycles that compute contact conditions from the cutter radius refuse to execute. Enter a valid positive radius in the tool list or select the correct cutting edge.

Likely causes

  • Radius column empty/zero in the tool list
  • Wrong D number (cutting edge) selected with unset radius
  • Tool data lost after battery/memory failure

Need the part urgently?

Send us alarm 61117 with your machine details — typical RFQ turnaround is 24–48h.