Siemens alarm 611U-A815: Power module temperature, pre-alarm

SIMODRIVE 611U drive alarm · SIMODRIVE 611D/611U

What it means

Warning-tier precursor of fault 515: heatsink temperature crossed the alarm threshold; if the condition persists the drive shuts down after about 20 s. Treat it as the last chance to clean filters/fans before production stops.

Likely causes

  • clogged air filters, failed fan
  • ambient temperature/altitude outside planning data
  • pulse frequency above module rating
  • duty cycle beyond S1/S6 rating of the power section

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 611U-A815 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog