Siemens alarm 611U-A815: Power module temperature, pre-alarm
SIMODRIVE 611U drive alarm · SIMODRIVE 611D/611U
What it means
Warning-tier precursor of fault 515: heatsink temperature crossed the alarm threshold; if the condition persists the drive shuts down after about 20 s. Treat it as the last chance to clean filters/fans before production stops.
Likely causes
- clogged air filters, failed fan
- ambient temperature/altitude outside planning data
- pulse frequency above module rating
- duty cycle beyond S1/S6 rating of the power section
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
cabinet fan/filter media
infeed · Primary suspect
- Request a quote →
6SN1123-… / 6SN1124-…
power-module · Check if others ruled out
Need the part urgently?
Send us alarm 611U-A815 with your machine details — typical RFQ turnaround is 24–48h.