What it means

The motor encoder signal level is too low, disturbed (screening), or cable-break monitoring responded. On HRS variants with 1Vpp encoders this message can also appear benignly during a controlled shutdown where only the drive's supply was switched off separately.

Likely causes

  • non-original or damaged encoder cable (use preassembled Siemens cables)
  • intermittent contact from cable-drag motion, crushed connector
  • shield not clamped under the top screw of the control module faceplate
  • toothed-wheel encoder gap out of tolerance
  • defective encoder or control module