Siemens alarm 611U-F510: Positive feedback identified

SIMODRIVE 611U drive alarm · SIMODRIVE 611D/611U

What it means

Two monitors share this fault: at ramp-up, rotor position versus encoder-reported position deviated by more than 45 degrees (like 611D alarm 300512); in operation, acceleration direction opposed the commanded torque direction, i.e. the drive pushed backwards. Siemens warns that operation must not resume until the cause is removed - risk of uncontrollable motion.

Likely causes

  • dirt/contamination on encoder or shifted encoder mounting
  • absolute-track fault, lost pulses, or damaged encoder cable
  • mechanically blocked axis driving torque into stall
  • monitoring window P1645/P1646 marginal on oscillating loads

Triage note: Check mechanics for blockage exactly as for speed-controller-at-limit before touching the encoder.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 611U-F510 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog