SIMODRIVE 611U drive alarm · SIMODRIVE 611D/611U

What it means

The DC link fell below permissible minimum P1162 because the upstream infeed went to a fault state or its supply collapsed. On UI-type infeed installations an overloaded pulsed resistor produces exactly this pattern during heavy braking.

Likely causes

  • line supply missing/phasing down at the infeed
  • infeed tripped internally (see infeed LED panel)
  • pulsed resistor overloaded or its thermal contact open
  • precharge/contactor chain dropping the bus under load

Triage note: Acknowledgement is RESET FAULT MEMORY; if it recurs under acceleration spikes, profile the bus voltage before swapping modules.