Siemens alarm 61212: Wrong tool type

SINUMERIK function alarm · Siemens 840D/810D powerline

What it means

The tool type coded in the tool data does not suit the operation the cycle is about to perform, for example calling a drilling cycle with a tool typed as a turning tool. Cycles evaluate the tool-type constant to pick kinematics and compensation behavior. Correct the tool type in the tool list or load a suitable tool.

Likely causes

  • Tool created with wrong type code in the tool list
  • Tool reused for a different operation than intended
  • Type field overwritten during data import