RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 61704

Siemens alarm 61704: Machined part contour missing

SINUMERIK function alarm · Siemens 840D/810D powerline

What it means

A stock-removal cycle expects the description of the finished part contour but none is available at the call position. Contour turning works by comparing finished part against blank; without the part contour the comparison is impossible. Provide the contour subroutine and reference it correctly in the cycle call.

Likely causes

  • Finished-part contour subroutine absent from program storage
  • Contour label/name mismatch in the cycle call
  • Contour blocks executed before the cycle instead of stored as subroutine

Need the part urgently?

Send us alarm 61704 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog