Siemens alarm 830000: Message: HiGraph group no. %A graph no. %N status %Z

SINUMERIK PLC message (mechanism) · Siemens 840D/810D powerline

What it means

Standard message generated by HiGraph sequencers running in the PLC: group number %A, graph (step-chain) number %N and status %Z are substituted at runtime. It demonstrates the sequencer/graph message mechanism of the 800000-899999 range, which Siemens reserves for sequences and graphs and leaves to the machine-tool builder to configure and describe. Meaning beyond the HiGraph status values is therefore defined by the OEM program.

Likely causes

  • HiGraph graph reached a monitored status/transitions
  • OEM-configured sequencer messaging enabled

Triage note: Message (not acknowledgeable alarm) from the MTB-configurable range 800000-899999 'Sequencers/graphs'; counterpart error form is 800000. Machine-tool builder range - texts and meaning are OEM-defined unless generated by the Siemens HiGraph standard shown here.

Need the part urgently?

Send us alarm 830000 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog