RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / A30031

Siemens alarm A30031: Power unit: Hardware current limiting in phase U

SINAMICS S120 drive warning · SINAMICS S120

What it means

The hardware current limiter for phase U responded and inhibited pulsing in that phase for one pulse period. Individual events are tolerated, but repetition escalates to fault F30017. The identical warnings A30032/A30033 cover phases V and W. Treat frequent occurrences as evidence of motor, cable or output-stage trouble.

Likely causes

  • transient motor overloads (crash, stick-slip)
  • motor cable faults or excessive length
  • controller gains too aggressive
  • weakening output-stage semiconductors

Triage note: Counterpart phases: A30032 (V), A30033 (W); escalation limit leads to F30017.

Need the part urgently?

Send us alarm A30031 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog