RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / F07011

Siemens alarm F07011: Drive: motor overtemperature

SINAMICS S120/G120 drive fault (motor) · SINAMICS S120

What it means

Motor temperature sensor (KTY84/PTC/PT1000) reports over-temperature beyond threshold.

Likely causes

  • blocked motor cooling fan / clogged fins
  • genuine overload (duty cycle, cutting load)
  • sensor circuit open or corroded connector (unrealistic r0035 reading)
  • winding insulation degrading

Triage note: Sanity-check r0035: e.g. 25 C reported on a hot motor = open sensor circuit, not thermal overload.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • motor blower/fan kit per motor type

    motor cooling fan · Primary suspect

    Request a quote →
  • motor per nameplate (1FK7/1FT6/1PH7)

    motor (sensor/winding fault) · Common cause

    Request a quote →
  • 6FX5002-2E… signal cable

    encoder/signal cable carrying thermo leads · Common cause

    Request a quote →

Need the part urgently?

Send us alarm F07011 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog