Siemens alarm F07900: Drive: motor blocked

SINAMICS drive fault (motion/monitoring) · SINAMICS S120

What it means

Speed controller sat at torque limit longer than p2177 while speed stayed below p2175 threshold - commanded rotation not happening.

Likely causes

  • mechanically blocked axis (crash, jammed ballscrew, brake still applied)
  • failed axis holding brake not opening
  • swapped motor phases / encoder direction mismatch
  • undersized drive hitting current limits
  • encoder feedback failure making drive think motor is stalled

Triage note: First verify shaft turns freely by hand with power off and listen/measure for brake release click; do not chase electronics first.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm F07900 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog