Siemens alarm F30001: Power unit: overcurrent

SINAMICS S120 drive fault (840D sl / 828D / SIMOTION) · Siemens 828D

What it means

Hardware overcurrent trip in the power unit - current exceeded shutdown threshold (typically ~2x rated).

Likely causes

  • output short circuit or earth fault in motor cable
  • motor winding fault
  • IGBT bridge failure inside motor module/power module
  • incorrect motor data or missing line reactor
  • motor oversized relative to the unit / wrong parameters

Triage note: Read fault value r0949 (measured current) and megger motor+cables BEFORE refitting any module; instant retrip under no load after external checks = dead power stage.