Siemens alarm F30005: Power unit: overload I2t
SINAMICS S120 drive fault · SINAMICS S120
What it means
Thermal I2t model of the power unit exceeded - sustained current above rated for too long.
Likely causes
- mechanical binding on axis (slides, ballscrew, gibs)
- counterbalance failure on vertical axes
- tool overload / blunt tool / excessive feeds
- drive undersized for duty cycle
- motor data mismatch causing overcurrent draw
Triage note: Symptom, not root cause in most cases: compare actual current (r0068/r0027) during the offending move against mechanics before buying hardware.