Siemens alarm F30012: Power unit: Temperature sensor heat sink wire breakage

SINAMICS S120 drive fault · SINAMICS S120

What it means

The connection to one of the heat-sink temperature sensors inside the power unit is interrupted. The fault value (r0949, hex bit map) identifies the affected zone: electronics slot, air intake, inverter sections 1-6 or rectifier sections 1-2. Because the sensors are internal, the module itself must be exchanged - no field repair path is offered.

Likely causes

  • broken internal temperature sensor wiring
  • defective module electronics (sensor input stage)
  • internal connector released after transport shock

Replacement parts