Siemens alarm F30015: Power unit: Phase failure motor cable

SINAMICS S120 drive fault · SINAMICS S120

What it means

Phase-failure monitoring in Servo or Vector drive objects detected a missing current in one motor phase. Chassis-format power units have no such monitoring - it applies to booksize Motor Modules. The alarm can also appear with a correctly connected motor when the speed control is unstable and produces oscillating torque, so controller tuning should be checked before replacing parts.

Likely causes

  • loose, broken or burnt conductor in one motor-cable phase
  • bad contact in the motor/power connector
  • unstable speed controller generating oscillating torque
  • drive stalled in U/f control with asymmetric currents (Vector)

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm F30015 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog