Siemens alarm F30015: Power unit: Phase failure motor cable
SINAMICS S120 drive fault · SINAMICS S120
What it means
Phase-failure monitoring in Servo or Vector drive objects detected a missing current in one motor phase. Chassis-format power units have no such monitoring - it applies to booksize Motor Modules. The alarm can also appear with a correctly connected motor when the speed control is unstable and produces oscillating torque, so controller tuning should be checked before replacing parts.
Likely causes
- loose, broken or burnt conductor in one motor-cable phase
- bad contact in the motor/power connector
- unstable speed controller generating oscillating torque
- drive stalled in U/f control with asymmetric currents (Vector)