Siemens alarm F30017: Power unit: Hardware current limit has responded too often
SINAMICS S120 drive fault · SINAMICS S120
What it means
The per-phase hardware current limiter (single events reported as warnings A30031/A30032/A30033) has tripped so often that the drive now shuts down with OFF2. On infeeds this typically means incorrect control parameters, overload, missing/wrong line reactor or a defective unit; on Motor Modules excessive load, cable faults or a failing power stage. The binary fault value names the phases involved (U/V/W).
Likely causes
- motor load too high or repeated acceleration into blockage
- motor cable short-circuit, ground fault or overlength
- incorrectly parameterized current/speed controller
- missing or wrong-type line reactor (infeed)
- defective power unit output stage
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
6SL3121-… Booksize Motor Module (match current rating)
motor-module · Common cause
Need the part urgently?
Send us alarm F30017 with your machine details — typical RFQ turnaround is 24–48h.