Siemens alarm F30021: Power unit: earth (ground) fault
SINAMICS S120/G120 drive fault · SINAMICS S120
What it means
Ground-fault monitoring detected leakage current from output phase(s) to protective earth.
Likely causes
- insulation breakdown in motor cable (coolant ingress common)
- motor winding ground fault
- damaged connector strain relief pinching conductors
- power-stage IGBT to heatsink short
Triage note: Megger motor and cable separately at the module terminals to localize before swapping electronics.