Siemens alarm F30037: Power unit: Rectifier overtemperature

SINAMICS S120 drive fault · SINAMICS S120

What it means

The rectifier section of the power unit overheated beyond its permissible limit. Besides the usual cooling and load causes, a line supply phase failure also raises rectifier stress and can trigger this fault. The fault value reports the rectifier temperature in 0.01 degC.

Likely causes

  • fan failure / insufficient cooling
  • overload or high ambient temperature
  • line supply phase failure increasing rectifier stress

Triage note: Acknowledge only after warning threshold A05004 has been undershot.

Need the part urgently?

Send us alarm F30037 with your machine details — typical RFQ turnaround is 24–48h.