Siemens alarm F30055: Power unit: Braking chopper overcurrent

SINAMICS S120 drive fault · SINAMICS S120

What it means

The braking chopper - the ballast circuit that dissipates regenerative energy in a resistor when no regenerating infeed is present - detected an overcurrent. This almost always means the braking resistor or its wiring is shorted or overloaded. The chopper stays disabled until the fault is acknowledged AND a new pulse enable is issued.

Likely causes

  • braking resistor short-circuit or internal failure
  • external braking resistor dimensioned too small (ohms/power)
  • chopper output stage defective

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm F30055 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog