Siemens alarm F30055: Power unit: Braking chopper overcurrent
SINAMICS S120 drive fault · SINAMICS S120
What it means
The braking chopper - the ballast circuit that dissipates regenerative energy in a resistor when no regenerating infeed is present - detected an overcurrent. This almost always means the braking resistor or its wiring is shorted or overloaded. The chopper stays disabled until the fault is acknowledged AND a new pulse enable is issued.
Likely causes
- braking resistor short-circuit or internal failure
- external braking resistor dimensioned too small (ohms/power)
- chopper output stage defective
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
6SN1113-… / 6SE7000-… braking resistor (match kW)
infeed · Common cause