Siemens alarm F30060: Pre-charge contactor state monitoring
SINAMICS S120 drive fault · SINAMICS S120
What it means
Feedback monitoring for the pre-charge contactor (ALM, SLM, BLM diode) or line contactor (BLM thyristor) did not return a correct signal within the monitoring time set in p0255[0]. The binary fault value distinguishes switch-in/out timeout, pre-charge contactor opening during pre-charge/infeed operation, and closing while the drive is OFF. This protects against running the infeed without a proven mains connection path.
Likely causes
- pre-charge/line contactor worn, welded or not pulling in
- auxiliary feedback contact or its wiring faulty
- monitoring time p0255[0] shorter than real contactor response
- contactor coil control (digital output/relay) failing