Siemens alarm F30600: SI MM: STOP A initiated

SINAMICS S120 drive fault · SINAMICS S120

What it means

The Safety Integrated function integrated in the Motor Module detected a fault and executed STOP A - pulse suppression via the module's own safety shutdown path. Typical triggers are an unsuccessful forced check of the safety shutdown path or the follow-up reaction to F30611 (defect in a monitoring channel). The decimal fault value identifies the source, including stop requests from the Control Unit and pulses-enabled/pulses-suppressed inconsistencies against STO state.

Likely causes

  • forced checking procedure of the safety shutdown path failed
  • follow-up response to fault F30611
  • internal defect in the Motor Module safety circuitry

Triage note: Remedy per manual: select STO and de-select again; replace Motor Module if persistent.