Siemens alarm F30630: SI MM: Brake control error
SINAMICS S120 drive fault · SINAMICS S120
What it means
The Safety Integrated function on the Motor Module detected a brake-control error and initiated STOP A. The decimal fault value localizes the problem: errors opening/closing the holding brake (p1278 settings, missing brake, wire breakage, ground fault in the brake cable, shorted brake winding), faults in the brake control circuit or CU-to-MM communication, and Safe Brake Adapter/Module states including brake released for service via X4.
Likely causes
- motor holding brake not connected, wire breakage or ground fault in brake cable
- short-circuit in the brake winding
- incorrect p1278 parameterization (only p1278=0 permissible with SBC)
- DRIVE-CLiQ communication error between CU and Motor Module
- defective Safe Brake Adapter/Module; EMC/shield routing deficiencies
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
6SL3362-… Safe Brake Adapter / SBC per setup
motor-module · Check if others ruled out
Need the part urgently?
Send us alarm F30630 with your machine details — typical RFQ turnaround is 24–48h.