Siemens alarm F30651: SI MM: Synchronization with Control Unit unsuccessful

SINAMICS S120 drive fault · SINAMICS S120

What it means

Safety Integrated requested synchronization of the safety time slices between Control Unit and Motor Module and this routine failed. The result is a STOP A that cannot be acknowledged by operator action. The manual prescribes POWER ON for all components and, if recurring, firmware upgrades of Motor Module and Control Unit - otherwise hardware replacement.

Likely causes

  • transient boot-up synchronization failure between CU and MM
  • mismatched CU/MM firmware versions
  • defective DRIVE-CLiQ connection used for safety communication
  • failing safety-related electronics in CU or MM