Siemens alarm F30657: SI CU: PROFIsafe telegram number invalid

SINAMICS S120 drive fault · SINAMICS S120

What it means

The PROFIsafe telegram number set in p9811 is not valid for the selected configuration: when PROFIsafe is enabled (p9801.3 = 1) a number greater than zero must be entered. The fault does not trigger a safety stop response but blocks proper PROFIsafe integration with the upper-level safety controller (e.g. 840D sl safety bridge). Purely a parameterization issue.

Likely causes

  • p9811 left at zero although PROFIsafe enabled
  • telegram number inconsistent with the PLC/safety project
  • safety program downloaded without matching telegram selection