Siemens alarm F30820: Power unit DRIVE-CLiQ: Telegram error

SINAMICS S120 drive fault · SINAMICS S120

What it means

The Control Unit received faulty telegrams from the power unit over DRIVE-CLiQ. The fault cause decodes the protocol violation: CRC/checksum error, telegram length mismatches, wrong address/type versus the receive list, SYNC problems, set error bit, or a telegram arriving too early. This is the classic symptom of a failing or marginally contacted DRIVE-CLiQ cable/plug somewhere between CU and module.

Likely causes

  • intermittent DRIVE-CLiQ cable or contaminated contacts
  • EMC coupling into the DRIVE-CLiQ line (routing near power cables)
  • mismatched topology/firmware causing list-type mismatches
  • defective DCL socket/transceiver on the component

Triage note: Check p9916 shutdown threshold; try another DRIVE-CLiQ socket (p9904) if available.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm F30820 with your machine details — typical RFQ turnaround is 24–48h.