Siemens alarm F31100: Encoder 1: Zero mark distance error

SINAMICS S120 encoder fault (Sensor Module / DRIVE-CLiQ encoder) · SINAMICS S120

What it means

The measured distance between consecutive zero marks does not correspond to the parameterized zero-mark spacing (p0424 linear / p0425 rotary). For distance-coded encoders the drive derives position confidence from these spacings, so a deviation means the incremental and reference tracks disagree. The fault value holds the last measured zero-mark distance in increments with sign of motion direction.

Likely causes

  • encoder coupling slipping or scale contaminated/damaged
  • EMC-induced signal distortion on the encoder cable
  • wrong zero-mark spacing parameterized (p0424/p0425)
  • aging or soiled encoder scan unit
  • defective encoder or encoder cable

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm F31100 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog