Siemens alarm F31100: Encoder 1: Zero mark distance error
SINAMICS S120 encoder fault (Sensor Module / DRIVE-CLiQ encoder) · SINAMICS S120
What it means
The measured distance between consecutive zero marks does not correspond to the parameterized zero-mark spacing (p0424 linear / p0425 rotary). For distance-coded encoders the drive derives position confidence from these spacings, so a deviation means the incremental and reference tracks disagree. The fault value holds the last measured zero-mark distance in increments with sign of motion direction.
Likely causes
- encoder coupling slipping or scale contaminated/damaged
- EMC-induced signal distortion on the encoder cable
- wrong zero-mark spacing parameterized (p0424/p0425)
- aging or soiled encoder scan unit
- defective encoder or encoder cable
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
6FX2001-… encoder cable (per interface)
cable · Common cause
Need the part urgently?
Send us alarm F31100 with your machine details — typical RFQ turnaround is 24–48h.