Siemens alarm F31101: Encoder 1: Zero mark failed
SINAMICS S120 encoder fault (Sensor Module / DRIVE-CLiQ encoder) · SINAMICS S120
What it means
Travel exceeded 1.5 times the parameterized zero-mark distance without a zero mark being detected. The drive therefore lost its reference-pulse stream - typical when the R-track signal is missing entirely, the cable is broken, or the axis moved beyond the expected mark pattern. The fault value counts increments since POWER ON or since the last accepted zero mark.
Likely causes
- reference (R) track absent due to encoder defect or soiled disk
- broken conductor in the encoder cable
- incorrect p0425 spacing setting for the encoder used
- plug contact failure between encoder and Sensor Module
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
6FX2001-… encoder cable
cable · Common cause
Need the part urgently?
Send us alarm F31101 with your machine details — typical RFQ turnaround is 24–48h.