RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / F31103

Siemens alarm F31103: Encoder 1: Amplitude error track R

SINAMICS S120 encoder fault (Sensor Module / DRIVE-CLiQ encoder) · SINAMICS S120

What it means

The amplitude of the reference-track signal (RP/RN) left its tolerance window - either the unipolar level exceeded roughly 3.5 V or the differential amplitude fell below about 1.6 V. Since homing and absolute-position checks rely on track R, the drive stops trusting the encoder. The hex fault value carries the instantaneous R-track level for diagnosis.

Likely causes

  • aged LED or soiled coding disk in the encoder
  • encoder speed range beyond the measuring equipment's frequency response
  • shielding/grounding deficiencies on the encoder cable
  • RP/RN conductors miswired or intermittent plug contact
  • defective encoder or encoder cable

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm F31103 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog