Siemens alarm F31110: Encoder 1: Serial communications error

SINAMICS S120 encoder fault (Sensor Module / DRIVE-CLiQ encoder) · SINAMICS S120

What it means

The serial protocol transfer between an absolute encoder (e.g. EnDat) and its evaluation module failed. The binary fault value is a rich diagnostic map: alarm bit in the position telegram, wrong quiescent level, no encoder response within 50 ms, CRC mismatch, acknowledgement errors, timeouts on cyclic/register communication, parity/frame errors and more. Each bit maps to a specific remedy in the manual - from EMC measures to replacing encoder, cable or Sensor Module.

Likely causes

  • EMC disturbance - missing/unconnected cable shield
  • incorrect encoder type selected versus actual device
  • defective encoder electronics
  • Sensor Module serial interface failing
  • parameterization mismatches (p0429, p0436, p0449)

Triage note: Interpret r0949 bit-wise; EnDat 2.2 details follow F31x35 semantics.