Siemens alarm F31111: Encoder 1: Absolute encoder internal error
SINAMICS S120 encoder fault (Sensor Module / DRIVE-CLiQ encoder) · SINAMICS S120
What it means
The absolute encoder's own fault word reports an internal problem. Group 0 bits cover failed illumination, low signal amplitude, incorrect position value, internal supply over/undervoltage/overcurrent and battery end-of-life; group 1 bits cover amplitude out of control range, multiturn/EEPROM/SAR converter faults and internal error-pin activation. Bits in group 0 generally mean replace encoder (or motor if the encoder has direct DRIVE-CLiQ); supply-voltage bits first warrant checking the SMC/cable path.
Likely causes
- encoder scanning head/LED defective
- internal 5 V supply fault in encoder or feed path
- battery exhausted on battery-backed multiturn encoders
- motor with integral DRIVE-CLiQ encoder failing internally
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
6SL3362-0AG00-0AA1 SME20 (if SMC path implicated)
sensor-module · Common cause
Need the part urgently?
Send us alarm F31111 with your machine details — typical RFQ turnaround is 24–48h.