RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / F31116

Siemens alarm F31116: Encoder 1: Amplitude error monitoring track A + B

SINAMICS S120 encoder fault (Sensor Module / DRIVE-CLiQ encoder) · SINAMICS S120

What it means

The rectified amplitudes of the sine/cosine incremental signals A and B (and the vector A^2+B^2) are outside tolerance. The nominal level must lie around 500 mV peak (375-600 mV window); monitoring responds below ~130 mV or above ~955 mV. The hex fault value shows both track levels simultaneously, revealing whether one channel died, both sagged, or levels drifted upward.

Likely causes

  • encoder signal amplitude drift from aging scanner
  • soiled or damaged incremental track
  • EMC/shielding problems attenuating or distorting signals
  • contact resistance in plugs; Sensor Module input stage defect

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm F31116 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog