RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / F31131

Siemens alarm F31131: Encoder 1: Deviation position incremental/absolute too large

SINAMICS S120 encoder fault (Sensor Module / DRIVE-CLiQ encoder) · SINAMICS S120

What it means

When cyclically reading the absolute position, the difference against the incremental position exceeded the limit (encoder-defined for EnDat, else 15 pulses), so the absolute value was rejected. On incremental encoders the check fires at zero-mark passages when marks deviate from their reference spacing. Typical field causes are contamination, strong magnetic fields disturbing the scale, or mechanical slip.

Likely causes

  • dirty or damaged coding disk/scale
  • strong ambient magnetic fields near the encoder
  • mechanical slip between scale and scanning head
  • EMC noise on encoder lines; wrong p0425 spacing setting
  • encoder electronics aging out of specification

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm F31131 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog