Siemens alarm F31875: Encoder 1 DRIVE-CLiQ (CU): Supply voltage failed

SINAMICS S120 encoder fault (Sensor Module / DRIVE-CLiQ encoder) · SINAMICS S120

What it means

The Control Unit learned from the DRIVE-CLiQ component that its power supply voltage has failed (fault cause 09h). The component named in the message value lost its 24 V feed - either its local supply tap or the upstream distribution. Since DRIVE-CLiQ carries both data and power, check connectors and the 24 V dimensioning feeding that node before replacing it.

Likely causes

  • 24 V feed to the DCL component open (cable, terminal, fuse)
  • overloaded 24 V budget for DRIVE-CLiQ components
  • intermitted contacts in the component's DCL connector
  • component internal supply converter failed