Siemens alarm F31885: Encoder/DRIVE-CLiQ: cyclic data transfer error
SINAMICS S120 DRIVE-CLiQ communication fault · SINAMICS S120
What it means
DRIVE-CLiQ cyclic communication error between control unit and involved encoder/component - telegrams corrupted or lost.
Likely causes
- DRIVE-CLiQ cable damaged (bend radius, chafing, rodent damage)
- loose/oxidized RJ45-M12 DRIVE-CLiQ connector
- 24 V feed to component missing/unstable
- failing transceiver in hub module (DME) or component
Triage note: Mapped on 840D sl screens into 23xxxx range (230000 power unit, 231000+ encoders, 236000 hub modules) with original SINAMICS number retained in alarm text/value.