Siemens alarm codes
364 alarms documented. Each entry explains the code, likely causes and the replacement part that resolves it.
SINUMERIK axis/spindle alarm
- 22053[Channel %1: ] Block %3 spindle %2 reference mode not supported
- 22055[Channel %1: ] Block %3 spindle %2 configured positioning speed is too high
- 22062[Channel %1: ] Axis %2 reference point approach: zero marker search velocity (MD) is not reached
- 22064[Channel %1: ] Axis %2 reference point approach: zero marker search velocity (MD) is too high
- 22296[Channel %1: ] Spindle %2 Error on gear stage change (cause: error code %3)
- 25001Axis %1 hardware fault of passive encoder
- 25010Axis %1 pollution of measuring system
- 25011Axis %1 pollution of passive encoder
- 25021Axis %1 zero mark monitoring of passive encoder
- 25022Axis %1 encoder %2 warning %3
- 25030Axis %1 actual velocity alarm limit
- 25031Axis %1 actual velocity warning limit
- 25042Axis %1 standstill monitoring during torque/force limitation
- 25060Axis %1 speed setpoint limitation
- 25070Axis %1 drift value too large
- 25080Axis %1 positioning monitoring
- 25100Axis %1 measuring system switchover not possible
- 25105Axis %1 measuring systems differ considerably
- 25110Axis %1 selected encoder not available
- 25200Axis %1 requested set of parameters invalid
- 25202Axis %1 waiting for drive
- 25220Axis %1 gear ratio changed with ESR enabled
- 26001Axis %1 parameterization error: friction compensation
- 26002Axis %1 encoder %2 parameterization error: number of encoder marks
- 26003Axis %1 parameterization error: lead screw pitch
- 26019Axis %1 encoder %2 measurement not possible with this controller module
- 26030Axis %1 encoder %2 absolute position lost
- 26040Axis %1 encoder parameterization MD %2[%3] has been adjusted.
- 26050Axis %1 parameter set change from %2 to %3 not possible
- 26105Drive of axis %1 not found
- 26106Encoder %2 of axis %1 not found
SINUMERIK 828D alarm
SINUMERIK axis alarm (encoder hardware)
SINUMERIK 808D alarm
SINUMERIK axis monitoring alarm (hardware-consequential)
SINUMERIK 840D sl / 828D drive umbrella alarm (PROFIdrive)
SINUMERIK axis alarm (encoder hardware, 611D)
SINUMERIK 840D sl drive communication alarm (PROFIdrive)
SINUMERIK 810/820 legacy alarm
SINUMERIK 840C legacy alarm
SINUMERIK NCK general alarm
SINUMERIK 840D/810D powerline drive alarm (SIMODRIVE 611D)
- 300007Axis %1 drive %2 not present or inactive
- 300100Axis %1 drive %2 drive power failure
- 300101Bus communications failure
- 300200Drive bus hardware fault
- 300201Axis %1 drive %2 timeout during access, error location %3
- 300202Axis %1 drive %2 CRC error, error location %3
- 300405Axis %1 drive %2 unknown drive alarm, code %3
- 300500Axis %1 drive %2 system error, error codes %3, %4
- 300501Axis %1 drive %2 maximum current monitoring
- 300502Axis %1 drive %2 maximum current monitoring of phase current R (measuring circuit error phase R)
- 300503Axis %1 drive %2 maximum current monitoring of phase current S (measuring circuit error phase S)
- 300504Axis %1 drive %2 measuring circuit error of motor measuring system
- 300505Axis %1 drive %2 measuring circuit error of absolute track, code %3
- 300506Axis %1 drive %2 NC sign-of-life failure
- 300507Axis %1 drive %2 synchronization error of rotor position
- 300508Axis %1 drive %2 zero mark monitoring of motor measuring system
- 300509Axis %1 drive %2 converter frequency exceeded
- 300510Axis %1 drive %2 error on actual current measurement zero balancing
- 300512Axis %1 drive %2 direct feedback recognized
- 300513Axis %1, drive %2 ground fault detected
- 300515Axis %1 drive %2 heat sink temperature alarm
- 300603Axis %1, drive %2 DC link voltage too high
- 300604Axis %1 drive %2 motor encoder is not adjusted
- 300606Axis %1 drive %2 flux controller at limit
- 300607Axis %1 drive %2 current controller at limit
- 300608Axis %1 drive %2 speed controller at limit
- 300609Axis %1 drive %2 encoder cut-off frequency exceeded
- 300610Axis %1 drive %2 rotor position identification failed
- 300613Axis %1 drive %2 maximum permissible motor temperature exceeded
- 300614Axis %1 drive %2 time monitoring of motor temperature
SINUMERIK 828D drive fault presentation (SINAMICS via PPU)
SINUMERIK PLC system alarm
- 400102Delete DB 2 in the PLC and restart
- 400201PLC STOP due to DB loading in the RUN state: DB%Z
- 400202Access error
- 400203DB acces error: DB%Z
- 400204Restart required
- 400250NCK sign-of-life monitoring
- 400251NCK has not started up
- 400252Error in internal communication with NCK
- 400253PLC STOP because of SPL system error
- 400254Checksum error found: %1
- 400260Failure of machine control panel 1
- 400262Failure of handheld unit
- 400264Pointer parameter machine control panel 1 incorrect
- 400274Direct keys 1 failed
- 400551Fault on MPI/DP bus
- 400552Fault on DP bus
- 400553Fault on PROFINET bus
- 400601Configuration of loading points incorrect
- 400604Set change with M06 in the machine data
- 400902Parameter ChanNo impermissible in FC9
- 410150Area in M group decoder list is too large
- 410151Magazine data for tool management missing in the PLC
- 411501Incorrect version of FB 15, > general reset, do not transmit FB 15 from project
- 411502Incorrect basic PLC program version
- 411503Error in the hardware configuration
- 428604Failure of a DP slave
- 428630Failure of the PROFINET IO system
- 430000F diagnostic: PLC project inconsistent
- 431001The safety mode of the F-PLC has been deactivated.
- 431003General error in the F program