Fagor alarm codes
375 alarms documented. Each entry explains the code, likely causes and the replacement part that resolves it.
CNC 8055 servo error
CNC 8055 hardware/feedback error (analog axes)
CNC 8060/8065/8070 CNC error
CNC 8058/8060/8065/8070 CNCelite EtherCAT error (Quercus drives)
- 24001EtherCAT: Datalink not found
- 24002EtherCAT: Missing package
- 24003EtherCAT: Wrong CRC
- 24004EtherCAT: Working Counter error
- 24255EtherCAT: Unknown error
- 24499EtherCAT: Node error. More information on diagnostics
- 24501Defective UM supply voltage
- 24507Restart the device after the watchdog
- 24659CoE emergency code: 0x%X, additional information: 0x%X
CNC 8060/8065/8070 servo/feedback error
- 3700Axis travel limit overrun (PLC)
- 3702Axis following error out of limit / Axis following error beyond limits
- 3705Home search required
- 3707Error when searching home
- 3708Maximum time to get into the in-position zone exceeded
- 3709Error when refreshing analog inputs
- 3710Position command values out of range
- 3711Error when refreshing CAN feedback reading
- 3712Home switch of the master axis is pressed when homing the slave axis
- 3715Overshooting in module compensation
- 3716Maximum velocity command exceeded
- 3717Some pulses got lost (not counted)
- 3726Drive Status Ready (DRSTAF/DRSTAS) of the tandem slave axis missing
- 3732Error in refreshing local counts
- 3733Error when refreshing local feedback reading
- 3736The axis has moved while the CNC was off
- 3738The axis has moved while the CNC was off
- 3751Drive Feedback not valid
- 3753Difference of position greater than MAXDIFREF. Press ENTER + RESET to confirm
- 3755Machine parameter PLOOPRESOL incompatible with drive version
CNC 8055 SERCOS drive error (DDS)
- 4000Sercos ring error
- 4001Undefined class 1 error
- 4002Overload (201...203)
- 4003Overtemperature at the drive (107)
- 4004Overtemperature at the motor (108)
- 4005Overtemperature at the heatsink (106)
- 4006Voltage control error (100...105)
- 4007Feedback error (drive standard errors 600...606)
- 4008Error at the power bus (213...215)
- 4009Overcurrent (drive standard error 212)
- 4010Overvoltage at the power bus (drive errors 304/306; 4011 = undervoltage, error 307)
- 4011Undervoltage at the power bus (307)
- 4013Position deviation too high (oriented/C-axis spindle)
- 4020DRIBUSID parameter value error
- 4021Spindle drive error : <code> (main-spindle qualifier)
- 4022Spindle-2 drive error : <code> (second-spindle qualifier)
- 4023Auxiliary spindle drive error (qualifier)
- 4027The drive has started up again
- 4028The light does not reach the CNC through the optic fiber
- 4029Communication with the drive cannot be established. No response
- 4056ERROR 100: Internal +5 V out of range
- 4057ERROR 101: Internal -5 V out of range
- 4058ERROR 102: Internal +8 V out of range
- 4059ERROR 103: Internal -8 V out of range
- 4060ERROR 104: Internal +18 V out of range
- 4061ERROR 105: Internal -18 V out of range
- 4062ERROR 106: Heatsink overheated
- 4063ERROR 107: VeCon card overheated
- 4064ERROR 108: Motor overheated
- 4065ERROR 200: Overspeed
- 4066ERROR 201: Motor overload
- 4067ERROR 202: Drive overload
- 4069ERROR 212: Over-current
- 4070ERROR 213: Undervoltage at the IGBT power driver
- 4071ERROR 214: Short-circuit
- 4072ERROR 215: Over-voltage at the power bus (Hard)
- 4073ERROR 300: Heatsink of the power supply module overheated
- 4074ERROR 301: Ballast circuit of the power supply module heatsink overheated
- 4075ERROR 302: Short-circuit at the ballast circuit of the power supply module
- 4076ERROR 303: Ballast circuit supply voltage out of range
- 4077ERROR 304: Over-voltage at the power bus detected by the power supply module
- 4078ERROR 305: Protocol error on the interface between the power supply module and the driver
- 4079ERROR 306: Over-voltage at the power bus (Soft, trigger prior to hardware)
- 4080ERROR 307: Under-voltage of the power bus
- 4091ERROR 500: Incoherent parameters
- 4093ERROR 502: Wrong parameter value
- 4096ERROR 505: Different RAM and Flash parameters
- 4105ERROR 701: Internal: Wrong VeCon board identification
- 4109ERROR 705: Power board identification error
- 4111ERROR 707: X4 motor feedback board identification error
- 4112ERROR 801: Encoder not found (motor feedback)
- 4115ERROR 804: Defective encoder (motor feedback)
- 4119ERROR 203: Torque overload error
- 4121ERROR 109: Over-voltage at digital inputs
- 4122ERROR 110: Low heatsink temperature
- 4136ERROR 254: Wrong reading of distance-coded reference marks (I0)
- 4137ERROR 308: Over-current at energy return circuit
- 4138ERROR 309: Short-circuit at the High Side IGBT
- 4139ERROR 310: Low voltage at the driver of the High Side IGBT
- 4140ERROR 311: Short-circuit at the Low Side of the IGBT
- 4141ERROR 312: Low voltage at the driver of the Low Side IGBT
- 4142ERROR 313: Consumption over-current
- 4143ERROR 314: I2t protection of the crowbar resistor
- 4151ERROR 506: .MOT file not found
- 4152ERROR 507: Motor not found in .MOT file
- 4157ERROR 811: Defective Feedback2 encoder (direct/second feedback)
- 4177ERROR 315: The power supply has not started up correctly
CNC 8060/8065/8070 SERCOS error
- 4001Parameter LOOPTIME different at the CNC and at the drive
- 4002Parameter OPMODE different at the CNC and at the drive
- 4004Parameter G00FEED higher at the CNC than at the drive
- 4005Following error monitoring not active at the drive
- 4008Sercos ring Error+ because the drive has been reset
- 4014Error when initializing the SERCON
- 4015TimeOut when initializing the Sercos ring
- 4016The drive is not a Fagor drive. Software option not allowed
- 4030Erroneous numbering of Sercos nodes