Fagor alarm codes
375 alarms documented. Each entry explains the code, likely causes and the replacement part that resolves it.
CNC 8055 SERCOS drive error (DDS)
- 4182ERROR 111: Undertemperature of the motor
- 4183ERROR 509: The activation code that activates the "open" option at the drive has not been entered.
- 4184ERROR 818: Error on the absolute track (FAGOR SSI absolute encoder)
- 4187ERROR 821: Image capturing sensor (CCD) error
- 4193ERROR 316: It took too long charging the DC bus of a compact drive
CNC 8060/8065/8070 SERCOS error
CNC 8060/8065/8070 SERCOS ring error
Fagor CAN/remote I/O error
- 4213SERCOS counter error (RCS-S remote counter)
- 5004CAN bus error
- 5005Presence control error detected by the CNC
- 5006Error because the node has been reset
- 5036Output over-current
- 5037Power supply voltage error
- 5065No communication with CAN drives
- 6004Error when initializing the BUS CAN
- 6006One or several CAN nodes do not respond
- 6011CAN error in remote node
- 6013Timeout when initializing the CAN
- 6027Hardware error in remote CAN node
- 6034Reset in CAN node
- 6050Short-circuit at the local I/O (over-current alarm)
CNC 8055 SERCOS drive error (third-party serial-encoder drives)
CNC 8060/8065/8070 CNC error
- 5000PLC error: The timer does not exist
- 5001PLC error: The counter does not exist
- 5002CNCRD: Unidentified variable
- 5003CNCWR: Unidentified variable
- 5010Division by zero at the PLC
- 5013Error when reading the digital inputs of the PLC
- 5014Error when writing the digital outputs of the PLC
- 6002The PLC program is not running
- 6003External emergency activated
- 6004Error when initializing the BUS CAN
- 6006One or several CAN nodes do not respond
- 6013Timeout when initializing the CAN
- 6023Error when initializing the handwheel counter
- 6024Error when initializing the keyboard handwheel
- 6032Error in the configuration of the CAN keyboard
- 6034Reset in CAN node
- 6036There is no voltage supply for local I/O
- 6040Error when reading the local jog
- 6050Short-circuit at the local I/O (over-current alarm)
- 6053Error when initializing the local jog
- 6054Error when initializing local handwheels
- 7002The tool is not in the magazine and ground tools are not allowed
- 7004Tool rejected or worn out (expired)
- 8010Error while loading the keyboard software
- 8023Disk memory below recommended minimum
- 8332#WARNING/#ERROR["Text <%d>"<,value>]/[integer]
- 8333#MSG["Text <%d>"<,value>]
- 8428(ERROR <integer> <,"text">)
- 85850G8585 not allowed with temporary origin G92 active
- 8820Message out of range
- 8822Error out of range
- 9014Fatal error. Duplicate module or not allowed
- 9016Resource out of the permitted range
- 9026End of module or subroutine 'END' missing
- 9054The COM port for MODBUSSVRRS cannot be opened
CNC 8060/8065/8070 feedback alarm (analog axes)
- 6000Feedback alarm (parameter FBACKAL active)
- 6001Tendency test alarm activated
- 6042Over-current alarm
- 6043Broken-cable alarm
- 6044Alarm for broken A signal cable
- 6045Alarm for broken B signal cable
- 6046Alarm for broken I0 signal cable
- 6047Alarm for broken AL signal cable
- 6048External feedback alarm
- 6049Amplitude alarm
- 6057Handwheel feedback alarm
DDS drive display code (AXD/SPD/ACD/SCD seven-segment)
- A.002Warning: motor temperature approaching limit (FM7 async spindle motors)
- E003Power bus voltage drops when torque is demanded
- E005Program code checksum error
- E006Error on the SERCOS board
- E100Internal +5 V out of range
- E106Extreme temperature at the heatsink (IGBTs)
- E107Drive overheated (CPU board / enclosure)
- E108Motor overheated
- E110Low IGBT heatsink temperature
- E156Excessive following error (axis lag)
- E157Too much difference in actual position between the two feedbacks (PP5)
- E159Wrong counting direction during GC3 phase-order test (phases swapped)
- E160Following error during emergency-stop braking ramp
- E200Overspeed (actual speed > 112% of SP10 maximum)
- E201Motor overload (motor I2t protection tripped)
- E202Drive overload (drive I²t tripped)
- E203Torque overload error (stalled motor)
- E205Insufficient voltage for demanded working conditions
- E206Velocity command exceeds SP10 maximum command
- E212Overcurrent
- E213Under-voltage at the driver of the IGBT
- E214Short-circuit at the drive module
- E215Power bus voltage too high (hardware trip)
- E250Home search error
- E253I0 not found in two revolutions
- E254Distance-coded I0 marks read wrong (direct linear feedback)
- E256Reference mark not repeatable per revolution of the feedback device
- E302Short-circuit in the ballast of the power supply module
- E412SERCOS synchronization error
- E505Motor ID mismatch between RAM and Flash memory
- E604Saturation in A and/or B signals of the MOTOR feedback (with E605: signals too low/damped)
- E605Feedback alarm: signals A/B of motor feedback too damped
- E606Excessive dispersion in rotor sensor signals
- E607Saturation in A and/or B signals of the DIRECT feedback (with E608: signals too low/damped)
- E609Damaged temperature cable
DDS drive display code (seven-segment; PS/XPS/RPS power supplies)
- E300Over-temperature at the heatsink of the power supply or compact module
- E301Over-temperature at the Ballast circuit of the power supply or compact module
- E304Power bus voltage too high (with E215 hard-trip and E306 software variants)
- E305Protocol error in the interface between power supply and drives
- E306Power bus voltage too high (software)
- E307Power bus voltage too low (software)
- E308Over-current in the regeneration circuit
- E313Consumption over-current (demand exceeds power supply)
- E314Crowbar overload error (I²t of crowbar resistor)
- E315Power supply start-up failure (with E316: compact-drive DC-bus charge timeout)
- E316Compact drive DC bus took too long to charge